FTS Report on DOY 156 I. The following are clock offsets, in microseconds between the clocks at each DSN complex and each complex relative to UTC(NIST). The offset is a mean of readings using several GPS space vehicles in common view. SPC10 SPC40 SPC60 SPC40 SPC60 MINUS MINUS MINUS MINUS MINUS MJD DOY NIST NIST NIST SPC10 SPC10 53881 146 1.309 0.627 -0.110% -0.677 -1.418% 53882 147 1.305 0.599 -0.106 -0.704 -1.401 53883 148 1.301 0.585 -0.104 -0.712 -1.401 53884 149 1.290 0.562 -0.102 -0.729 -1.390 53885 150 1.290 0.564 -0.098 -0.737 -1.373 53886 151 1.282 0.493 -0.092 -0.776 -1.375 53887 152 1.277 0.486 -0.091 -0.785 -1.370 53888 153 1.271 0.474 -0.087 -0.794 -1.351 53889 154 1.267 0.446 -0.086 -0.818 -1.347 53890 155 1.259 0.421 -0.086 -0.834 -1.351 53891 156 1.254* 0.400* -0.080* -0.851* -1.335* 53892 157 1.249* 0.377* -0.077* -0.868* -1.327* II. Frequency Offsets from linear least-squares fits on time-offsets over the period (53881 to 53890): |------------------------------|-----------|-------------|-----------| | | DELTA-F/F | UNCERTAINTY | STD. DEV. | | MEASUREMENT | (E-13) | (+/- E-13) | (nsec.) | |------------------------------|-----------|-------------|-----------| | SPC10 RELATIVE TO UTC(NIST) | -0.648 | 0.018 | 1.656 | | SPC40 RELATIVE TO UTC(NIST) | -2.659 | 0.163 | 12.738 | | SPC60 RELATIVE TO UTC(NIST) | 0.342 | 0.023 | 1.838 | | SPC40 RELATIVE TO SPC10 | -1.988 | 0.083 | 6.526 | | SPC60 RELATIVE TO SPC10 | 0.908 | 0.076 | 5.927 | |------------------------------|-----------|-------------|-----------| III. Comments: * Values derived from linear least squares extrapolation or interpolation % Due to UPS failure at SPC60 on DOY 145 (MJD 53880), a time step was introduced to synchronize with NIST.